Single Jet – MID R80

  • MID Approved
  • Working pressure: 16 Bar
  • 360° Rotating dial
  • For cold (30°C) or hot (90°C) water
  • Brass body
  • 5 Black rollers (Cubic Metre)
  • 3 Red rollers (Submultiples)
  • Pointer minimum reading 0.01 litres
  • Sensitivity index
  • Real performances exceed EEC & ISO standards
  • Counter perfectly sealed (hermetic)

Description

  • Size (mm) – Refers to inside bore diameter.
  • Max Flow Rate (Q m3/h) – Refers to the emergency flow rate in the event of system failure. Damage may result.
  • Nominal Flow Rate (QN m3/h) – Typical application for every day usage.
  • Transitional Flow Rate (L/hr) – Point at which the flow rate is high enough to achieve a level of accurate measurement.
  • Minimum Flow Rate (L/hr) – The absolute minimum flow required for the unit to function.
  • EEC Approved Class – The EEC Classification system used to measure accuracy at very low flow rates.
  • Standard ISO4064/BS5728/EEC Specification Class B applies.
  • When ordering please state whether for hot or cold use. Suffix Part No. with C (Cold) or H (Hot) and please advise of preferred pulsed output at time of ordering.
  • Figures apply to both hot and cold meters.
  • Pressure drops on all sizes are generally below 0.2 bar.
Part No. Dn Size Body Length Length with couplings Height Width
D15SJ 1/2 110204 73760.75
D20SJ3/4 130234 73.5 760.80